Komatsu — Komatsu PC290NLC-6K and PC290LC-6K Hydraulic Excavator Operation & Maintenance Manual

24. SERVICE PROCEDURE 24.2 WHEN REQUIRED 24.2.1 CHECK, CLEAN AND REPLACE THE AIR CLEANER ELEMENT WARNING Never clean or replace the air cleaner element with the engine running. When using pressured air to clean the element, wear safety glasses or goggles to protect the eyes. Checking If air cleaner clogging monitor y flashes, clean the air cleaner element. y BP00100 Cleaning or replacing the outer element 1. Open the front door on the left side of the machine, remove wing nut x and take out element c . To prevent entry of dirt and dust, cover the air connector side of the rear end of the air cleaner with a clean cloth and adhesive tape. 2.

Clean interior of the air cleaner body interior and the cover. 3. Direct dry compressed air (less than 700 kPa (7 kg/cm 2 , 100 psi)), to element c from inside along its folds, then direct it from outside along its folds and again from inside. 1) Replace the outer element if it has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. 2) Replace both inner and outer elements when the monitor lamp y start flashing soon after installing the cleaned outer element even though it may not have been cleaned 6 times. 3) Check inner element mounting nuts for looseness and , if necessary, retighten. PC290-ENG 3-30