24. SERVICE PROCEDURE Rinse filter with clean water from the fine filter side. 6. Dry filter, compressed air may be used, but apply air from fine filter side. B 7. Refit filter element ensuring coarse filter side is facing outwards. Notice. The normal cleaning interval is 100 hours, however if the ma- chine is used at a dusty side, shorten this interval. A Clean recirculation air filter (air conditioner option only.) 1. Remove 4 bolts on the upper side of the luggage tray and remove bracket a . 2. Remove 4 bolts on the lower side and lift away luggage tray b . If radio is fitted, disconnect radio connector first by removing radio (us- ing special tools provided). 3.

Pull filter elements c out of air conditioner housing. 4. Clean as fresh air intake filter (note recirculation air filter is homog- enous and can be fitted in either direction). 5. Re-install. PC290-ENG 3-54