Komatsu — Komatsu PC290NLC-6K and PC290LC-6K Hydraulic Excavator Operation & Maintenance Manual

24. SERVICE PROCEDURE 6. Bleeding air from attachment (if installed) For machines equipped with attachments such as the breaker, actu- ate the attachment pedal about 10 times to bleed the air completely from the attachment circuit while running the engine at low idling. NOTICE If the attachment bleeding procedure is specified by the manu- facturer, bleed the attachment according to such procedure. 7. Operation 1. After completion of bleeding the air, stop the engine, and wait for at least 5 minutes before starting operations. In this way, the air bubbles are removed from the oil inside the hydraulic tank. 2. Check for any leakage of oil, and wipe off any oil that has been spilled.

PC290-ENG 3-76