11. EXPLANATION OF COMPONENTS m n o 13. CAB LAMP SWITCH This lights up the cab lamp. ON position: Lights up The cab lamp can be turned on even when the starting switch is at the OFF position, so be careful not to leave it on by mistake. 14. PUMP CONTROL OVERRIDE SWITCH When normal: Switch is down When abnormal: When the monitor display shows E02 (PC valve system error), it is possible to carry out operation when this switch is moved up. The pump control override switch is designed to allow operations to be carried out for a short period when there is an abnormality in the pump control system (PC valve system error). The abnormality must be re- paired immediately. 15.
SWING LOCK OVERRIDE SWITCH When normal: Switch is down When abnormal: When the monitor display shows E03 (swing brake system error), the brake is cancelled and it becomes possible to swing the upper structure when this switch is moved up, so normal operations can be carried out. However, the swing brake remains cancelled. The swing lock override switch is designed to allow operations to be carried out for a short period when there is an abnormality in the swing brake electrical system (swing brake system error). The abnormality must be repaired immediately. PC290-ENG 2-19