Komatsu PC160-6K, PC180LC-6K, PC180NLC-6K, PC200EN-6K, PC200EL-6K — Komatsu PC160-6K, PC180LC-6K, PC180NLC-6K, PC200EN-6K, PC200EL-6K User Manual

24. SERVICE PROCEDURE 24. 7 EVERY 2000 HOURS SERVICE Maintenance for every 50, 100, 250, 500 and 1000 hours should be carried out at the same time. 24.7.1 CHANGE OIL IN FINAL DRIVE CASE AX WARNING The oil is at high temperature immediately after the machine has been operated. Wait for the oil to cool down before carrying out maintenance. | if there is still pressure remaining inside the case, the oil or plug may fly out. Loosen the plug slowly to release the pressure. Prepare the following. Container to catch drained oil: Min. 4 7 capacity Refill capacity: 4 7 (1.05 US gal, 0.9 UK gal) Handle 1. Set the TOP mark at the top, with the TOP mark and plug ® perpendicular to the ground surface. 2.

Set a container under plug © to catch the oil. 3. Remove plug ® and © with the handle and drain the oil. REMARK Check the O-rings in the plugs for damage. If necessary, replace with new ones. 4. Screwin plug ©. 5. Add engine oil through the hole of plug ©. For details of the oil to use, see 20. “USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”. 6. GL F 19610 When the oil overflows from the hole of plug ©, install plug ®. Tightening torque of plugs ® and ©: 70 + 10Nm (7 + 1 kgm, 50 + 7 3-72 PC160/180/200-6k-ENG Ibft).