MAINTENANCE LUBRICATOR --- IF EQUIPPED 1. Lubricator Operation (1) Turn power switch (8) ON to activate the pump (1). Grease is sucked up and supplied to high-pressure grease gun (3). 8 2 IMPORTANT: When the pump begins to suck grease, any air inside pump (1) will be mixed in, making grease turn whitish. Open check valve cock (2) to bleed this air-mixed grease. Securely close check valve cock (2) when all air-mixed grease is bled out. 1 M111-07-011 (2) Open front right cover (9), turn switch (10) ON. (3) Take out grease gun (3) from front right cover (9). Get high-pressure grease gun (3) and pay out the hose from hose reel (4) to the length required.
(4) Press hydro-chuck (5) protruding from high-pressure grease gun (3) into a grease nipple and pull the gun le- ver (11) to discharge grease. 9 (5) Release the gun lever (11) when greasing is complete; grease discharge will stop. 10 IMPORTANT: When detaching hydro-chuck (5) from grease nipple (7), grease nipple (7) tip may break unless a special care, is taken, as follows: • Tilt nozzle (6) a little so as to release the connecting pressure applied to hydro-chuck (5). • Slowly detach hydro-chuck (5) from nipple (7).
M1J7-07-040 9 (6) When all greasing work is complete, turn power switch (8) OFF, then pull grease gun (3) lever to release remain- ing pressure from grease gun (3), pump (1), and the hose so as to ensure long life of the components. A little grease will be discharged at this time. 11 5 M1J7-07-042 3 6 NOTE: The hose has a limited service life. Periodically inspect the hose for cracks, grease leakage, or any other dam- age. If any damage is found, replace the hose. 5 7 M111-07-013 7-17