hitachi — 850.indb

MAINTENANCE 2 Change Coolant --- twice a year (in spring and autumn) NOTE: Before leaving the Hitachi Factory, the cooling system is filled with a mixture of water and Genuine Hitachi Long-Life Coolant. As long as Genuine Hitachi Long-Life Coolant is used, the service intervals between changing the coolant is once every two years, or every 4000 hours, whichever comes first. WARNING: Do not loosen the radiator cap until the system is cool. Loosen the cap slowly to the stop. Re- lease all pressure before removing the cap. SA-039 3 1. Remove cover (3) of radiator drain cock. 2. Remove the radiator cap.

Open drain cocks (1) and (2) on the radiator and engine block to allow the coolant to drain completely. 3. Close drain cocks (1) and (2). Fill the radiator with tap wa- ter and a radiator cleaner agent. Start the engine and run at a speed slightly higher than slow idle; when the needle of the temperature gauge reaches the green zone, run the engine for about ten more minutes. 4. Stop the engine and open drain cock (1). Flush out the cooling system with tap water, until draining water is clear. This helps remove rust and sediment. M1JB-07-014 5. Close drain cock (1). Fill the radiator with tap water and an anti-rust agent or antifreeze at the specified mixing ratio.

When adding coolant, do so slowly to avoid mixing air bubbles in the system. 1 6. Run the engine to sufficiently bleed the air from the cool- ing system. 7. After adding coolant, operate the engine for several min- utes. Check the coolant level again, and add coolant if necessary. M1JB-07-015 2 M17V-07-033 7-60