hyundai 250LC-7 — 8(-1,2,3,4,5).doc

3. CHARGING CIRCUIT When the starter is activated and the engine is started, the operator releases the key switch to the ON position. Charging current generated by operating alternator flows into the battery through the battery relay (CR-1). The current also flows from alternator to each electrical component and controller through the fuse box. 1) OPERATING FLOW (1) Warning flow Alternator "I" terminal I/conn CN-3(4) CPU alternator level CN-51(9) Cluster charging warning lamp(Via serial interface) (2) Charging flow Alternator "B + " terminal Battery relay(M8) Battery(+) terminal Fusible link CN-60 Fuse box 2) CHECK POINT GND :

Ground 4 -8 Engine Start switch Check point Voltage Run ON ①- GND(Battery voltage) ②- GND(Battery relay) ③- GND(Alternator B+ terminal) ④- GND(Alternator I terminal) ⑤- GND(CPU) 20~30V