Komatsu — TIPS FOR LONGER UNDERCARRIAGE LIFE

. OPERATION OPERATION MEASURING LINK PITCH 3 - 126 INSPECTION AND REP Frequent inspection and p rompt repair will reduce repair costs. The following items for ins pection will serve as a guide to maintenance service of each undercarriage part. P periodical inspection and limits and reversing limits. 1. Insert a wooden block between track shoe and sprock et to take up the slack in track s 2. Measure the pitch len gth (L) of 4 links at a straight p ortion at least 2 links from mas ter pin (A). Divide this measurement by four to obtain the link pitch. 216.3 mm (8.5 in) rning bushing: 219.3 mm (8.6 in) w on the master link. Basic link pitch (P): Link pitch limit for tu rning bushing:

219.3 mm (8.6 i There is no link windo REMARK The measured value unde r decimal of link pitch is different from t he basic value depending u pon the precision of measure or the if it isn't worn out. he tolerance of product even Don't judge it's worn out to o soon, do it with the trend of m easured value after that. MEASURING HEIGHT OF G After taking up slack in t rack shoes, measure height at center of shoe as shown below. Standard height (h): 72 m Repair limits: 25 mm (1.0