Komatsu — 3.6.1 AUXILIARY HEATER FOR OPERATOR’S CAB

OPERATION 3.6 OPERATING THE HEATER, VENTILATION AND AIR CONDITIONING 3.6.1 AUXILIARY HEATER FOR OPERATOR’S CAB Special Equipment The auxiliary cab heater is mounted on the bracket (2) below the stair to the operator’s cab. View -X- shows the arrangement of components and the flow of water, fuel and air. Legend for illustration Z26082 (1) Fuel tank (2) Mounting bracket for heater unit (3) Heater unit HYDRONIC 10, refer to the separate operation manual HYDRONIC 10 for all operating and maintenance instructions. The manual is filed in volume 2 binder.

(4) Water supply line from engine to cab heater (5) Water return line from cab (6) Valve block with thermostatic function (7) Water line to auxiliary heater (8) Hot water line from auxiliary heater to cab heater (9) Fuel shut off-cock for fuel supply to heater (3) (10) Fuel strainer (11) Fuel supply line (12) Fuel dosing pump (13) Combustion air intake line (14) Exhaust muffler (15) Engine (16) Cab heater Operation To activate the heater (3), open fuel shut off-cock (9). Select the desired heating stage with the control module (5) shown on page 97. Water flow schematic of auxiliary heater, detail -Y- Water temperature below 67°C: Flow from A to B and from E to D. Port C closed.

Water temperature above 67°C: Flow from A to B and from E to D. Port C slightly opened. Water and engine at operating temperature: Flow from C to B and from E to D. Port A closed. REMARK During the warm season the fuel shut-off cock (9) should be closed. 145