OPERATION 3.7 POWER HOUSE 3.7.1 EMERGENCY ENGINE SHUTDOWN SWITCHES Legend for illustration Z26286 (1) Pulling chains for emergency shut down from ground man (special equip- ment). When one of the chains (1) is being pulled down for emergency shut down of the engine, the Operator will be informed by the following message, displayed on the VHMS monitor: * # Motor shut down has been actuated from ground man* (2) Battery main switch keys NOTICE After switching OFF the main key switch in the Operator’s cab, wait at least 3 minutes before switching OFF the battery main switches. The Vehicle Health Monitoring System (VHMS) needs this period for saving data.
If batteries are switched OFF before this time period is over, data will be lost. (3) Emergency engine shutdown switch (S33a) on radiator door (4) Emergency engine shutdown switch (S33b) at the power house wall, opposite to the main control valves (5) Emergency engine shutdown switch (S33c) in pump compartment on the central control and filter carrier (6) Maintenance safety switch (S58) for start prevention of the Diesel engine, see next page for more information (A) Push button of emergency shutdown switches (3, 4 and 5) for stopping the engine In case of emergency push in the button (A) to stop the engine. Never stop the engine from a full load except in case of emergency.
If a hot engine is shut down without previous idling period of three to five minutes, the temperature in certain engine parts rising sharply after the cooling sys- tem ceases to function. The resulting thermal stress, especially in the turbochargers, may cause serious dam- age. NOTICE For releasing button (A) turn it to the right, the button returns to normal position. The engine can then be started in the normal way at the control panel in the oper- ator's cab. The engine can not be started with button (A) in depressed position. When one of the Shutdown switches (3 - 5) is activated, the VHMS display informs the Operator by a correspond- ing message. 147 WARNING WARNING