OPERATION 3.7 POWER HOUSE 3.7.2 MAINTENANCE SAFETY SWITCH AND BATTERY MAIN SWITCHES Legend for illustration Z26286 (6) Maintenance safety switch (S58) for start prevention of the Diesel engine. This switch is located inside the power house, next to the front door. (7) Rotary switch Switch positions: -0- Engine start blocked -1- Normal operation (8) Securing flap for rotary switch in -0- position (9) Holes for attaching padlocks Before beginning any maintenance operations set the rotary switch (7) to -0- position to prevent starting of the engine during maintenance. Fold up flap (8) and secure this position by inserting a padlock into the holes (9) of flap (8) and safety switch (6).
Up to ten padlocks can be attached. (10) Light switch (S15) on front door for interior power house lighting (11) Plug socket 24V DC (12) Light switch (S15a) on rear door for interior power house lighting Before working on the batteries or any other part of the electrical system remove both battery main switch keys (2). Batteries give off highly inflammable gas! Never allow sparks or open flame near the batteries! Avoid spilling any electrolyte on hands or clothing. Repair or replace all broken wires immediately. All termi- nals must be clean and securely fastened; never paint connections. DO NOT short across or ground any terminals of the bat- teries.
Make sure that all machinery house doors are securely closed before starting the engine and during operation of the shovel. 149 WARNING WARNING WARNING CAUTION CAUTION