OPERATION 3.7 POWER HOUSE 3.7.3 CENTRAL CONTROL AND FILTER PANEL Legend for illustration Z 23021 (1) Central control and filter panel (2) Valve bank (2.1) Valve block, pump load limiting circuit (2.2) Valve block, fixed pump 1and 3 for swing (2.3) Valve block, pilot oil circuit (2.4) Valve block, pump control circuit (2.5) Valve block, travel circuit (2.6) Valve block, swing circuit (2.7) Valve block, hydraulic access ladder circuit (2.8) Valve block, hydraulic swing down service arm circuit (3) Change over valve lever for operation modes of pump control system. Lever Positions: E - Electronic operation mode (normal operation mode) H - Hydraulic operation mode (e.g.
for testing purposes) REMARK The standard operation mode of the pump control system is the Elec- tronic Operation Mode. For testing purposes the pump control system can be changed to the hydraulic operation mode. In case of a failure in the electronic control sys- tem use the hydraulic operation mode to continue operation.
(4) Pressure oil filter for hydraulic oil cooler fan drive circuit (5) Pressure oil filter for pump control and pilot oil circuit (6) Pressure oil filter for PTO gear lubrication circuit (7) Pressure oil filter for engine radiator fan drive circuit Pressure Switches (B16) Swing brake (B17) PTO lubrication oil (B21) Radiator fan drive oil filter (B22) Pump control and pilot oil filter (B27) PTO lubrication oil filter (B28) Oil cooler fan drive oil filter (B48) Travel parking brake (B85) Pump control oil pressure X1 (B86) Pilot oil pressure X2 151