Komatsu — 3.8.1 STANDARD COMPONENTS IN CAB BASE

OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE 3.8.1 STANDARD COMPONENTS IN CAB BASE REMARK On shovels with electrical pre-heating systems there are addi- tional components in the cab base. Refer to page 167 for more information. The cab base contains two batteries which are located in separate boxes at the left wall. Batteries emit highly explo- sive gas! Sparks or flame can cause the gas to explode. DO NOT smoke or use open flame when entering the cab base. DO NOT weld or grind near the batteries. DO NOT short across or ground any terminals of the batteries. On removal always disconnect the ground (-) cables first. when reinstalling the batteries connect the positive (+) cables first.

The cab base may contain high tension electrical appli- ances. Access to the cab base for authorized service staff only. DO NOT touch cables and their terminals and connected components. Always contact authorized Electricians having the permission to work on medium and high volt- age systems. Legend for illustration Z26086 (1) Cab base door. Keep the door always locked, access to the cab base for authorized personnel only.

(2) Door handles (3) Lock rod for locking the cab base door in open position (4) Light switch (5) Controller of the VHMS system (6) Programmable logic controller (PLC) (7) Electronic pump control module (RC4) (8) Main switch board (X2), refer to page 157 for switch board components. (9) Signal horn compressor (10) Back-up batteries for the programmable logic controller (PLC) 155 WARNING WARNING WARNING WARNING