OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE Checking diagnostic fault codes of the engine electronic controlled fuel system QUANTUM and of the engine monitoring system CENSE REMARK With the engine diagnostic enable switch in ON position, the three indicator lamps (H94.1) STOP, (H95.1) WARNING, and (H96.1) FLUID will illumi- nate and stay illuminated if no faults are present. If active faults are present, then fault code flashout will start if the engine diagnostic switch is ON and the engine is off. QUANTUM faults will be flashed out on the red STOP indicator lamp and CENSE faults will be flashed out on the yellow WARNING indica- tor lamp.
The white FLUID lamp will remain on as long as a fault condition is present. To check for active fault codes proceed as follows: 1. Stop the engine and turn the Excavator main key switch to OFF position. 2. Turn the engine diagnostic enable switch to ON position. The diagnostic switch is located on the operator console, see page 95 for more information. 3. All active QUANTUM faults are flashed out first on the red STOP indicator lamp (H94.1). After all QUANTUM fault codes are flashed out, the active CENSE fault codes will be flashed out on the yellow WARNING indicator lamp (H95.1 ). The fault code flash out will begin with the first active QUAN- TUM fault.
The first digit will be flashed out (0.3 seconds between each flash), followed by a 1 second delay; then the second digit will be flashed out, followed by the third digit. There will be a 2 second delay before the next fault is flashed out. Once all QUANTUM fault codes are flashed out, CENSE fault codes will start to flash out on the yellow WARNING indi- cator lamp (H95.1). The same timing sequence, described above, is used for the CENSE faults. Once all faults have been displayed, there will be a 3 second delay before the fault code flashout begins again. Active faults must be corrected as soon as possible. Contact your Komatsu dealer for repair.
REMARK For more information, refer to the separate Engine Operation and Maintenance Manual filed in volume 2 binder. 161 CAUTION CAUTION