OPERATION 3.8 ELECTRICAL EQUIPMENT IN CAB BASE Pre-heating System (continued) Heaters for Hydraulic Oil Reservoirs, PTO Housing, Engine Oil Reserve Tank and Batteries, illustration Z26085 (1) Control box for hydraulic oil heating. This box is located in the cab base, see page 167 (2) Switch, hydraulic oil heating ON / OFF. (3) Indicator light green, hydraulic oil heating ON. (4) Warning light red, heating system failure.
(5) Immersion heaters installed in the suction oil reser- voir and engine oil reserve tank (6) Immersion heaters installed in the main hydraulic oil reservoir (7) Immersion heater installed in the PTO (pump distrib- utor gear) (8) Thermostats installed in the main oil reservoir, suc- tion oil reservoir, PTO (pump distributor gear) and in the engine oil reserve tank (9) Adapter flange for heater element (10) Heater plates for batteries REMARK The batteries are located below the walkway floor plates in front of the machinery house.
(A) Location of immersion heaters (6) at the main oil res- ervoir (B) Location of thermostats (8) at the main oil reservoir and engine oil reserve tank (C) Location of immersion heaters (5) at the suction oil reservoir and engine oil reserve tank 173