OPERATION 3.18 FIRE DETECTION AND SUPPRESSION SYSTEMS FIRE DETECTION AND SUPPRESSION SYSTEMS The mining shovel is equipped with the following systems: CHECKFIRE SC-N ELECTRIC DETECTION AND ACTUA- TION SYSTEM DRY CHEMICAL FIRE SUPPRESSION SYSTEM LT-A-101 LIQUID AGENT FIRE SUPPRESSION SYSTEM LVS The CHECKFIRE SC-N system provides automatic fire detection and automatic or manual actuation of the fire suppression sys- tems. If the CHECKFIRE SC-N system detects a fire it will auto- matically actuate the suppression systems in two steps.
First the DRY CHEMICAL FIRE SUPPRESSION SYSTEM LT-A-101 will be actuated and after a 20 second delay the LIQUID AGENT FIRE SUPPRESSION SYSTEM LVS will be actuated. The dry chemical portion of the twin agent system is primarily responsible for the suppression. Although the LVS wet chemical solution is primarily intended for cooling, it can also aid in sup- pression by two means: The water content of the solution cools the fuel and the sur- roundings surface areas. Cooling the surrounding surface areas minimizes the change for reflash. Forming a film over the fuel, which aids in securing against reflash.
For detailed description of the above systems refer to the sepa- rate Inspection and Maintenance Manuals filed in volume 2 binder. Before operating the Shovel make sure the Fire Detection, Actuation and Suppression systems are operative. Carry out inspection and maintenance according to the sepa- rate manuals CHECKFIRE SC-N ELECTRIC DETECTION AND ACTUATION SYSTEM and FIRE SUPPRESSION SYSTEMS in volume 2 Binder. This section covers only such information necessary for the operator to understand operation of the fire detection and actuation system. All other information i.e.
placing the system in service, daily inspection, functional tests, maintenance and trouble shoot- ing are contained in the separate manuals. 223 WARNING WARNING CAUTION CAUTION