Komatsu — 3.18 FIRE DETECTION AND SUPPRESSION SYSTEMS

OPERATION 3.18 FIRE DETECTION AND SUPPRESSION SYSTEMS Legend for illustration Z 21619 (A) Control module with manual/automatic actuator in the Operator’s cab (1) Control module, refer to the separate Manual "CHECKFIRE SC ELECTRIC DETECTION AND ACTUATION SYSTEM" for all information concern- ing - Operational Modes, Daily Inspection, Mainte- nance and System Conditions -. (2) Strike button, manual actuation (3) Ring pin (4) Manual / automatic actuator (5) LT-5-R cartridge (6) Manual actuator switch at the radiator door (7) Manual actuator switch at the rear power house door (8) High level alarm on operator’s cab (9) Pressure switch - DPST located in the cab base.

This switch shuts off the engine immediately when the fire detection system has a fire detected. The reset plunger (10) moves out into its upper position. When the fire suppression system has been recharged, push in the reset plunger. (10) Reset plunger, be sure to push in this plunger as soon as the fire suppression system has been recharged after actuation of the system. (11) Fire extingushing tanks on power house roof 225