OPERATION 3.18 FIRE DETECTION AND SUPPRESSION SYSTEMS 3.18.5 LOCATION OF THE EXTINGUISHING AGENT TANK ASSEMBLIES AND EXPELLANT GAS CARTRIDGES ON POWER HOUSE ROOF Legend for illustration Z25570 - A - Components of the dry chemical fire suppression system LT-A-101 - B - Components of the liquid agent fire suppression sys- tem LVS (1) Extinguishing agent tank assembly of the dry chemical suppression system LT-A-101 (2) Name plate (3) Fill cap (4) Extinguishing agent tank assembly of the liquid agent fire suppression system LVS (5) Relief valve (6) Manual actuator switch at the radiator door (7) Manual actuator switch at the rear power house entrance (8) From automatic detection system (9) Extinguishing agent outlet to nozzle (10) Pressure switch for engine shutdown (12) Mounting clamp (15) Expellant gas Nitrogen cartridge (20) Pneumatic actuation line REMARK Check Extinguishing agent tank assemblies (1 and 4) and Expellant gas cartridges (15) for good condition and proper mounting.
Check filling level of Extinguishing agent tank assembly (1) of the dry chemical suppression system LT-A-101 according to the instructions in the separate Inspection and Maintenance manual LT-A-101 VEHICLE FIRE SUPPRESSION SYSTEM. When checking the filling level, make sure the extinguishing pow- der is not compacted. Stir up the extinguishing powder with a suit- able stick until it is in a free flowing condition. 231