4.6 LUBRICATION AND MAINTENANCE SCHEDULE MAINTENANCE (*) The hydraulic oil change intervals can be extended for a further time period, when an oil sample analysis shows a positive result. When extending the oil change interval, it is necessary to carry out an oil sample analysis after every 1000 operating hours. However, it is recommended to change the hydraulic oil after 6000 operating hours at the latest. REMARK The pulsation damper of the hydraulic oil cooler cir- cuit must be replaced after every 2000 operating hours. (1) Perform maintenance according to separate Engine Operation an Maintenance Manual filed in volume 2 binder.
(2) Perform inspections according to the separate Manual FIRE SUPPRESSION SYSTEM filed in volume 2 binder. NOTICE The Lubrication oil Pump for Pump Distributor Gear Lubrication should be replaced with a new pump after every 5000 operating hours. To ensure proper functioning of the seat belt replace the seat belt and securing parts after every three years. 274 Service Intervals Service Point Service See Every 2000 operating hours or yearly. Hydraulic system Change oil (*) Replace suction strainers (*) Replace pulsation damper page 439 Emergency escape ladder Inspect page 451 Fire detection and actuation sys- tem Maintenance (3) Every 3000 operating hours however at least once a year.
Swing gears and Motor adapter housings Change oil page 453 Travel gears, Brake housings and Motor adapter housings Change oil page 461 Final drives (Drive shaft housings) Change oil page 465 PTO (Pump distributor gear) Change oil page 473 Engine Maintenance (1)