MAINTENANCE 4.6 LUBRICATION AND MAINTENANCE SCHEDULE 4.6.6 EXTENDED SERVICE INTERVALS FOR ENGINES EQUIPPED WITH ENGINE OIL MANAGEMENT SYSTEM Reserve System Oil Flow Schematic, illustration Z25458 (1) Reserve oil tank, usable contents 457 liters. (2) Oil level sight gauge. Check oil level in the reserve tank before starting the engine. If necessary refill reserve tank via service arm adapter, refer to page 239 for more information. (3) Pumping unit, located on the side member of the power frame. (4) Oil filter of the supply system. Replace both filter ele- ments after every 500 operating hours.
(5) Crankcase breather filter (6) Suction lines (7) Oil supply line from pump (3) to engine oil pan (8) Withdrawal oil line from oil pan to pump (3) (9) Oil feed-back line to reserve tank (1) (10) Reserve tank breather filter (11) Oil drain plug (12) Power frame side member Servicing Intervals Every 10 operating hours Check oil level in engine oil reserve tank (1) on sight gauge (2). Keep oil level between MIN and MAX mark on the gauge. Check also the oil level in the engine oil pan. REMARK The oil level in the engine oil pan can vary between the MIN and MAX marking on the oil level gauge depending on the operat- ing condition of the reserve system when the engine was stopped.
With sufficient oil in the reserve tank and with the reserve system in proper working order, there is no need to fill the engine oil pan even with the oil level at the MIN mark on the gauge. If the oil level is below the MIN marking on the gauge, corrective action must be taken. Fill the reserve tank and check the reserve sys- tem. The function of pumping unit (3) is monitored by an indicator light located on the "X2" switch board in the cab base. 281