MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY 4.9.5 FINAL DRIVE HOUSINGS - CHECK OIL LEVEL (Drive Shaft Housings) Legend for illustration Z 19087 (1) Oil level gauge (2) Oil filler plug (3) Breather filter REMARK The breather filters for the final drives are mounted inside the center frame and connected with extension hoses. Check oil level by removing oil level gauge (1). Oil level must be between upper and lower mark on gauge (1). If necessary top up fresh oil through filler opening (2) up to the upper (max.) mark on gauge (1).
CHECK BREATHER FILTERS Check the breather filters located inside the center frame, of the travel gears, motor adapter housings and final drives, for restric- tion. If necessary, remove breather filters, blow out with com- pressed air from inside to outside and reinstall. 323