Komatsu — 4.9.8 HYDRAULIC OIL COOLERS - INSPECT AND CLEAN IF NECESSARY

MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY 4.9.8 HYDRAULIC OIL COOLERS - INSPECT AND CLEAN IF NECESSARY See illustration Z 20369 Provide adequate working platform for safe access to the hydraulic oil coolers. Before removing mounting bolts (1) of the hydraulic oil cooler door (2) check to make sure that all door hinges are in good condition and properly fastened on their car- rier frames. If cracks are found at the welded joints of the hinges, DO NOT remove mounting bolts (1) otherwise the cooler door may become detached and fall off. Danger of accidents. Have the damage repaired as soon as possi- ble.

Never clean the oil coolers with the engine running or with the cooler fans still rotating. 1. Loosen mounting bolts (1) and open door (2). Details (A and B) in the illustration show LH hinged oil cool- ers. The description below applies also to RH hinged oil cool- ers. 2. Loosen fasteners (3) and swing out oil coolers (4 and 5). 3. Secure door (2) and oil coolers (4 and 5) with locking bars (7, 8 and 9). 4. Clean the oil coolers with compressed air, hot pressure water or steam cleaner. Use only clear water for cleaning the cool- ers. Direct the flow from inside to outside. When using a steam cleaner, wear safety glasses and protec- tive clothing. Hot steam can cause serious personal injury.

5. After cleaning, swing back the oil coolers to their home posi- tion. 6. Disengage locking bars (7, 8 and 9) and fix them in storage position (10). Swing back inner cooler (5). Take care guide pin (A) fits into hole (B) of main frame (6). Secure cooler (5) with fastener (3). Swing back outer cooler (4); observe (A - B) and secure with fastener (3). Close door (2); observe (B - A). Install mounting bolts (1) and tighten securely. 7. After cleaning the oil coolers, inspect the hydraulic hose lines. 329 WARNING WARNING CAUTION CAUTION WARNING WARNING