MAINTENANCE 4.10 EVERY 250 OPERATING HOURS OR MONTHLY Service the in-line grease filter as follows: 1. Unscrew plug (18), illustration Z 21465, using 36 mm width wrench and remove packing ring (19). 2. Take out spring (21), spring guide (22) and element (12). 3. Clean all parts and inspect for damage. Replace as neces- sary. 4. Assemble all parts according to the illustration. Make sure all sealing surfaces are clean. Take care for proper position of spring guide (22). 5. Install plug screw (18) with new packing ring (19) and tighten with a wrench. Check breather filter (16) Check condition and fastening of breather filter (16). If necessary clean the breather filter with compressed air.
For removal of the breather filter it is necessary to lift off the container cover. Make sure the breather filter mounting nut inside the cover is securely tightend before lowering the cover onto the container. 337