MAINTENANCE 4.10 EVERY 250 OPERATING HOURS OR MONTHLY 4.10.9 AIR CONDITIONING FOR OPERATOR’S CAB - CHECK REFRIGERANT LEVEL Legend for illustration Z 22591 (1) Air conditioner door with filter mat (2) Air conditioner unit (3) Sight glass for checking refrigerant filling (4) Shut-off valve on dryer cartridge (5) Dryer cartridge (6) Refrigerant collector reservoir (7) Condenser (8) Condenser blower (9) Low pressure switch (10) High pressure switch (11) Expansion valves (12) Evaporator blower (13) Evaporator (14) Cool air outlets Checking the refrigerant level: Switch on air conditioning equipment and run at maximum capac- ity for approx. 5 minutes. Observe inspection glass (3).
A refrigerant flow loaded with bub- bles or foam indicates a lack of refrigerant. In this case well equipped refrigeration specialists must check the circuit for tight- ness and must add the missing quantity or refrigerant. If more than 200 grams per year are lost, the oil level of the refrigerant compressor must also be checked. This is a special procedure and must be carried out by refrigeration specialists only. Isolated small bubbles in the inspection glass may be neglected. Even with an absolutely tight equipment a certain amount of refrigerant is lost through the walls of the hoses. Therefore a small annual replenishment of the refrigerant quantity is normal.
The dryer cartridge (5) must be replaced after every 1000 operat- ing hours or once a year by refrigeration specialists. Clean the filter mats of condenser (7) and evaporator (13). REMARK Servicing of the air conditioning systems is restricted to work- shops especially equipped for this purpose. Refer to the separate booklet ”AIR CONDITIONING” in Service Literature Binder – Vol- ume 2 for more information. 345