MAINTENANCE 4.11 EVERY 500 OPERATING HOURS OR MONTHLY 4.11.3 PTO (PUMP DISTRIBUTOR GEAR) MAIN PUMP DRIVE SHAFT HOUSINGS - CHECK OIL LEVEL Legend for illustration Z 21657 (1) Oil level gauge (2) Oil filler plug (3) Breather filter (4) Oil collector reservoir for secondary oil pump drive shaft housings (5) Breather filter with oil level gauge (6) Main pump drive shaft housings (7) Oil level plug of main pump drive shaft housing (8) Oil filler plug with breather pipe of main pump drive shaft housing (9) Oil drain plug of main pump drive shaft housing (10) Oil drain plug of PTO gear CHECK OIL LEVEL OF ALL MAIN PUMP DRIVE SHAFT HOUSINGS The Oil level should be at the lower edge of level plug opening (7).
If necessary remove filler plug with breather pipe (8) and add oil through the filler opening up to the level opening (7). Check breather pipe for obstruction, if necessary blow out with compressed air. Re-install plug (7) and plug (8) with breather pipe and tighten securely. If pump removal becomes necessary, drain the drive shaft hous- ing oil by removing drain plug (9). Be sure to fill the drive shaft housing up to the filler opening (7) after mounting of the pump. REMARK If oil starts dropping out at one of the breather pipes (8), the oil seal ring of the respective pump drive shaft must be checked and replaced if necessary. 351