Komatsu — 4.11.7 GROUND CABLE OF OPERATOR’S CAB - CHECK FOR CORRECT CONNECTION

MAINTENANCE 4.11 EVERY 500 OPERATING HOURS OR MONTHLY 4.11.7 GROUND CABLE OF OPERATOR’S CAB - CHECK FOR CORRECT CONNECTION Legend for illustration Z25520 (A) Ground cable fixing point inside the operator’s con- sole (B) Ground cable fixing point in the cab base on the lower left mounting bolt of the (X2) switch board (1) Ground cable from operator’s console to the lower left mounting bolt of the (X2) switch board (2) Cab heater water lines Check ground cable 1. Remove both battery main switch keys. 2. Open the dashboard of the operator’s console and secure with the prop rod provided. 3. Check cable (1), view (A) for good condition and secure fas- tening. 4.

Close the dashboard and secure with the clamps provided. 5. Check cable (1) in the cab base, view (B) for good condition and secure fastening on the lower left mounting bolt of the (X2) switch board. Be sure to replace a worn or damaged cable or fastening part without delay. Loose or missing ground cables can cause fire, serious injury or death. 363 WARNING WARNING