Komatsu — 4.12.1 HIGH STRENGTH BOLT CONNECTIONS

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Retightening procedure of the crawler carrier mounting bolts REMARK The required tightening torque for the mounting bolts of the crawler carriers has been determined and applied during the assembling procedure of the excavator at the mine site. This pro- cedure has to be repeated one time after the first 1000 operating hours through your Komatsu dealer. General The required tightening torque for all mounting bolts (M48), illus- tration Z25572 has to be determined with the four measuring bolts (7), which dimension is analogous to the mounting bolts.

The required axial tensioning force of the bolts (M48) is deter- mined by means of the elongation of the bolts. For determination of the tightening torque, two especially pre- pared measuring bolts (7) are installed on each crawler carrier. The measuring bolts can be identified by the centering dot at the bolt head and the milled area at the shaft end. Necessary equipment for the retightening procedure: Measuring device (1 - 6) delivered with the new machine, see table below. Special hydraulic torque wrench, see illustration Z24072 on page 407. This tool will be provided by your Komatsu dealer. Measuring Device PN 92847640 403 Position Part name Part No. Qty.

1 Angle bar 928 475 40 1 2 Dial gauge 092 706 40 1 3 Screw M5x16 502 515 98 1 4 Feeler 477 172 40 1 5 Bolt M10x25 307 777 99 2 6 Washer 517 122 98 2 7 Measuring bolts (installed) 933 613 40 4