Komatsu — 4.12.1 HIGH STRENGTH BOLT CONNECTIONS

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Procedure for determination of the tightening torque for the crawler carrier mounting bolts after the first 1000 operating hours, see illustration Z25572 1. Loosen the two measuring bolts (7) at the left crawler carrier and the two measuring bolts at the right crawler carrier. Do not lubricate the measuring bolts. 2. Tighten the four measuring bolts (7) with 150 Nm. 3. Attach the measuring device (1 - 6). 4. Set the dial gauge (2) to the zero position. 5. Attach the special hydraulic torque wrench (1), see illustration Z24072 on next page to the measuring bolt (7). 6.

Increase the pressure at the hydraulic torque wrench until a torque of 2100 Nm is reached and tighten the measuring bolt. 7. Record the pressure and the change of the bolt length in a table. 8. Increase the pressure further by steps of 10 bar until the required elongation of 1,0 mm of the measuring bolts (7) is reached. 9. Record the corresponding hydraulic pressures in a table. 10. Repeat this procedure on all four measuring bolts (7). 11. Add the 4 determined hydraulic pressures and then divide by 4 to obtain an average value. 12. Now loosen only one of the mounting bolts (M48) and tighten up to the determined average pressure. DO NOT loosen more than one bolt at the same time.

DO NOT lubricate the bolts (M48). 13. Repeat this procedure step by step at all of the 124 mounting bolts (M48) . 405 CAUTION CAUTION