MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH 4.12.8 MACHINERY HOUSE DOORS - INSPECT AND LUBRICATE DOOR HINGES Provide adequate working platform for safe access to the rear machinery house door (2). Check all door hinges (3) for good condition and proper fastening to their carrier frames. If cracks or distortion at the weld area of the hinges are found corrective action must be taken. Legend for illust. Z25187 (1) Front doors of machinery house (2) Rear door of machinery house (3) Door hinges (4) Grease fitting (5) Cotter pin Lubricate all door hinges (3) at grease fittings (4). Check to make sure that the hinge pins are properly secured with cotter pins (5).
437 WARNING WARNING