MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER NOTICE The hydraulic oil change intervals can be extended for a fur- ther time period, when an oil sample analysis shows a posi- tive result. When extending the oil change interval, it is necessary to carry out an oil sample analysis after every 1000 operating hours. However, it is recommended to change the hydraulic oil after 6000 operating hours at the latest. The pulsation damper must be replaced after every 2000 operating hours. Legend for illust.
Z 21689 (1) Main oil reservoir (2) Back-pressure valve (3) Return oil collector pipe (4) Drain coupling (5) Hand wheel of main shut-off valve (6) Return oil strainer (7) Bolt (8) Bolt (9) Intermediate pipe (10) Gasket (11) Gaskets (12) Compensator Evacuate main hydraulic oil reservoir according to section Central Refilling System on page 238. On machines without transfer pump for hydraulic oil attach drain hose (part of tool set) to coupling (4) and drain oil from return oil collector pipe (3). Drain also the oil from return oil mani- fold, see illustration Z 21690 and from suction oil reservoir, see illustration Z 21691A.
On machines with transfer pump for hydraulic oil, proceed according to page 232. REMARK Replace return oil strainer (6), illustration Z 21689 after major repairs on the hydraulic system and after every 6000 operating hours. Use new gaskets (10 and 11). With hydraulic oil reservoir empty, service the return oil filters and inspect the reservoir for sediments. Clean the reservoir if neces- sary. 439