MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER Legend for illust. Z 21691A (1) Suction oil reservoir (2) Drain coupling (3) Suction oil strainer (4) Bolts (5) Intermediate pipe REMARK On the bottom of the intermediate pipe there is a cover for inspection of strainer (3), see detail (A). (6) Gaskets (7) Inspection cover (8) Drain coupling (9) Gasket Replace suction strainer (3) Attach drain hose (part of tool set) to coupling (2) and drain oil from suction oil reservoir. Remove intermediate pipe (5) and strainer (3). Install new strainer (3) with new gaskets (6).
REMARK For inspection of strainer (3) between oil changes proceed as follows: 1. Close main shut-off valve (5), illustration Z21689. 2. Attach drain hose to coupling (8), illustration Z21691A and drain the oil from intermediate pipe (5). 3. Inspect strainer (3) and replace if necessary. 4. Install cover (7) using a new gasket (9). 5. Open main shut-off valve. 6. Bleed the air from suction oil reservoir according to the instructions on page 449. 443