MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER Bleed air from all Hydraulic Pumps and check the Oil Level in the four Main Pump Housings Legend for illust.
Z 21693 I - IV Main hydraulic pumps (swash plate type) (1) Axial piston pump for hydraulic oil cooler fan drive (2) Axial piston pump for engine coolant radiator fan drive (3) Piggy-back gear pump for pump regulation and pilot oil circuit (4) Piggy-back gear pump for PTO gear lubrication system (14) Oil level and filler plug of main pump housing (15) Port of leakage oil return line Bleeding air from pumps (1 - 4) and main pumps (I - IV) Bleeding air from the hydraulic pumps and complete filling of the suction oil reservoir and the suction lines is essential, to prevent damages caused by air in the suction system (cavitation). Proceed as follows: 1. Open vent plug on top of pumps (1 and 2).
Close the vent plugs as soon as bubble-free oil flows out. 2. Open vent plug (13), illust. Z22513 on the suction port of gear pumps (3 and 4) and wait until bubble-free oil flows out. Then tighten vent plug (13). 3. Open vent plug (13) on the pump suction port of all four main pumps. As soon as bubble free oil flows out tighten vent plug (13). Check oil level in main pump housings (I - IV) 1. Remove level and filler plug (14), illust. Z 21693. The oil level in the pump housing must reach the lower edge of the open- ing. 2. If necessary add hydraulic oil up to the lower edge of the filler opening. 3. Insert level and filler plug (14) and tighten securely.
NOTICE Make sure the main pump housings are correctly filled, otherwise the pump drive shaft bearings could be dam- aged due to lack of lubrication. Check hydraulic oil level. Check the whole hydraulic system for leakages. 449