MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR Brake Housing - Change Oil (Siebenhaar) 1. Remove level gauge (8), illustration Z 21694, drain plug (9) and breather filter (7). Drain the oil into a receptacle of approx. 5 liter capacity. 2. Clean breather filter (7) with compressed air from inside to outside and re-install. 3. Install drain plug (9) and fill-up engine oil SAE 10 or hydraulic oil HLP 32 through filler opening up to the lower mark on level gauge (8) and install the level gauge. DO NOT overfill the brake housing, otherwise the brake could be damaged due to overheating. 4. After short operating period check oil level and housing for leaks.
NOTICE Be sure to fill the brake housing and motor adapter housing with engine oil or hydraulic oil as specified on page 265. Motor Adapter Housing - Change Oil 1. Remove level gauge (6) and drain plug (5). Drain the oil into a receptacle of approx. 5 liter capacity. 2. Install drain plug (5) and fill-up engine or hydraulic oil through filler opening, up to the "MAX" mark on level gauge (6) and install the level gauge. 3. After short operating period check oil level and housing for leaks. 459