Komatsu — 4.14.4 TRAVEL GEARS AND MOTOR ADAPTER HOUSINGS MANUFACTURED BY "ZOLLERN"- CHANGE OIL

MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR 4.14.4 TRAVEL GEARS AND MOTOR ADAPTER HOUSINGS MANUFACTURED BY "ZOLLERN"- CHANGE OIL Legend for illustration Z 25897 (1) Oil level gauge for travel gear (2) Oil filler plug (3) Adapter for breather filter hose line (4) Drain plug (5) Level and filler plug for motor adapter housing. (6) Oil drain plug for motor adapter housing (7) Hydraulic motor TRAVEL GEARS - CHANGE OIL REMARK The breather filters for the travel gears are mounted inside the center frame and connected with extension hoses. 1. Remove drain plug (4), filler plug (2) and oil level gauge (1).

Check breather filter, mounted inside center frame, and clean as necessary. 2. After the oil is completely drained, flush the gear with the reg- ular gear oil and reinstall drain plugs (4). 3. Fill the gear with fresh oil through filler opening (2) up to the "Max" mark on oil level gauge (1). 4. Install filler plug (2) and gauge (1). 5. After short operating period check gears for leakage. 467