Komatsu — 4.14.6 PTO (PUMP DISTRIBUTOR GEAR) - CHANGE OIL

MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR 4.14.6 PTO (PUMP DISTRIBUTOR GEAR) - CHANGE OIL Legend for illustration Z 21657 (1) Oil level gauge (2) Oil filler plug (3) Breather filter (4) Oil collector reservoir for secondary oil pump drive shaft housings (5) Breather filter with oil level gauge (6) Main pump drive shaft housings (7) Oil level plug of main pump drive shaft housing (8) Oil filler plug with breather pipe of main pump drive shaft housing (9) Oil drain plug of main pump drive shaft housing (10) Oil drain plug of PTO gear Gear Oil Viscosity Select gear oil viscosity grade according to ambient tempera- tures.

If the new gear oil has a different viscosity grade compared with the drained oil it is necessary to enter the new viscosity grade into the appropriate ”Service SETTINGS” group of the VHMS Menu Control. Change the OiI 1. Remove drain plug (10). 2. Remove gauge (1) and filler plug (2). 3. Remove breather filter (3), blow out with compressed air from inside to outside and re-install. 4. After the oil is completely drained, flush the gear with the reg- ular gear oil and reinstall drain plug (10). 5. Fill in new oil through opening (2) up to the “MAX” mark on gauge (1). DO NOT screw in gauge (1) for checking the oil level, see detail (A). 6. Re-install parts (1 and 2). 7.

After short operating period, check oil level and housing for leakage. 473