OPERATION 3.3 OPERATOR’S CAB - CONTROLS EURO Control Pattern Legend for illustration Z25460 (1) Control lever for stick and swing machinery (2) Control lever for boom and bucket (3) Toggle switch for engine speed selection Low idle – High idle (4) Push button for Truck counter number 1 (TR1) For counting loaded trucks press this button. The total number of trucks loaded is shown on the VHMS monitor field TR1, refer to page 98 for more information. A second truck counter switch is located on the control panel, refer to page 89 for more information. NOTICE The push button (4) has a second function.
When the Vehicle Health Monitoring System is switched to the PM CLINIC group within the SERVICE MENU, selected PM CLINIC data can be frozen by pushing button (4). Frozen data can then be stored in the PM CLINIC MEMORY. For more information refer to the SERVICE MANUAL VHMS-System. (5) Swing speed switch. This switch has two positions: Left side down - Normal swing speed. Right side down - Increased swing speed. It is recommended to use the higher swing speed for slewing angles greater than 90°. (6) Signal horn button (7) Travel control pedal, left track forward - reverse (8) Travel control pedal, right track forward - reverse (9) Slew brake pedal For more information see page 202. 81