MAN — Removing and installing heat exchanger pipe cluster

Removing and installing heat exchanger pipe cluster D Drain coolant, see page 49 Note: If sufficient space is available near the en- gine, the pipe cluster can be removed while the heat exchanger remains in place. The pipe cluster (length: 805 mm) is pulled out of the side of the housing. If the engine is installed, there is usually not enough space in the engine room. The heat exchanger must therefore be re- moved from the engine (see page 61). 1 Fig. 1 In the installed condition the collar of the pipe cluster is visible between cover and heat ex- changer housing (arrow). Mark position of pipe cluster relative to heat ex- changer. Figs. 2 and 3 Remove both covers (width across flats:

13 mm). Take off the O-rings. 2 3 Fig. 4 Carefully knock pipe cluster out from the other end, using a block of wood. 4 63