Removing and installing pipe cluster for heat exchanger from D 2842 LE 404 engine Removing pipe cluster for heat ex- changer D Remove heat exchanger, see page 61 Fig. 1 In the installed condition the collar of the pipe cluster can be seen between the cover and the heat exchanger housing (arrow). Match-mark the position of the pipe cluster relative to the heat-exchanger housing. 1 Fig. 2 Remove both covers. Take off O-rings. 2 Fig. 3 Remove the two screw plugs from the rear side of the heat exchanger. Once these screw plugs are removed, two stud bolts are visible. 3 Fig. 4 Remove the two stud bolts.
These hold the pipe cluster in a fixed position relative to the heat ex- changer (or expansion tank). 4 65