Changing impeller of raw water pump Fig. 5 If no extractor is available, pull out impeller to- gether with the eccentric, using a pair of pliers. 5 Fig. 6 Installation is to be carried out in reverse se- quence. Apply sealant to cam before installing it. Lightly coat new impeller with vaseline prior to its installation. Dry running will destroy the impeller. Fill pump with water prior to operation. Check for leaks. 6 72