Starter/Starter 10. Pull springs back to remove two field coil brushes from brush holder. Remove brush holder. M37123 -UN-25JAN90 M98,2060K,40 -19-05NOV85 11. Use an ohmmeter or test light to check for continuity. Touch one probe of tester to brush mounting plate and other probe to each of the field coil brush holders (A). If there is continuity, replace the brush holder assembly. M37139 -UN-29JAN90 M98,2060K,41 -19-05NOV85 CTM2 (19APR90) 60-17 16, 18, 20 & 24HP Onan Engines AllTractorManuals.com 130495 12. Pull spring back to remove negative brush. Measure brush length. Replace brush if worn below minimum length of 11.5 mm (0.45 in.).
-UN-25JAN90 M37124 -UN-25JAN90 M37125 M98,2060K,42 -19-05NOV85 60 17