31. HANDLING AUTO-GREASING SYSTEM 1. Check that a pail or grease is in the grease pump case. If there is not sufficient grease in it, supply new grease. 2. Check that grease does not leak from the piping between the pail or grease pump case 1 and follower plate 2 . NOTICE If follower plate 2 is not used, pump 3 cannot suck up the grease even if there is sufficient grease in the pail. Accordingly, do not remove the follower plate. The pails of the following sizes are available. Use follower plate 2 of the proper size for each size of the pail. For applicable combinations of pails, follower plates 2 and level gauges 4 , see the above table. 3.
Turn the starting switch ON and check that lamp 5 on the monitor panel lights up. Lighting: Normal Flashing: There is not sufficient grease in the grease pump. If the lamp still flashes after grease pump is filled with grease, consult your Komatsu distributor. 5-24 Part No. of follower plate Applicable pail Level gauge 427-S95-2510 Inside diameter of pail ø275 – ø290 mm 427-S95-2570 427-S95-2520 When pail is not used 427-S95-2530 For use in Japan (Pail is used) 427-S95-2560