31. HANDLING AUTO-GREASING SYSTEM 31.4 METHOD OF SETTING TIMER The timer is installed to control the greasing interval of the auto- grease system. The timer is installed in box 1 at the rear of the operator’s seat. The greasing interval can be changed freely according to the following table with the blue dial of the timer. The set interval has an error of about ±15%, however (for both stopping and starting). Examine: When timer is set to 11.25 minutes 1. Adjustment of greasing interval Timer box 1 is in the position shown at right.
Power supply for timer Even after the starting switch is turned off, both interval time and operating time are stored in this circuit board by the capacitor (Super Cap) for about five days, and the next operation starts under the condition when the power was turned off previous time. If the power is kept turned off for more than five days, however, the memory is canceled. 2. Method of adjusting interval time (Blue dial) Open the door at the rear lower of the cab, then open the timer box. Turn the dial shown at right to adjust the interval time and operating time. To adjust the interval time, turn blue rotary switch 1 in the figure at right according to the following table.