. MAINTENANCE MAINTENANCE PROCEDURE EVERY 1000 HOURS MAINTENANCE Carry out the EVERY 100 HOURS MAINTENANCE, EVERY 250 HOURS MAINTENANCE, and EVERY 500 HOURS MAINTENANCE at the same time. REPLACE HYDRAULIC OIL FILTER ELEMENT WARNING and may cause burns. Wait for the 4 - 65 The parts and oil are at high te temperature to go down before st When removing the oil filler cap, t urn it slowly to release the internal pressure, the NOTICE f the machine is equipped with a h ydraulic breaker, the hydraulic oil will deteriorate much faster than during normal bucket operations. For details, see "MAI maintenance. NTENANCE INTERVAL FOR HYDRAULIC BREAKER (PAGE 4-17)" when carrying out 1.
Set the work equipment on the hard and flat ground in the maintenanceposture as show n in the figure, then lower it to the ground and stop the engine. 2. Remove the cap from oil fil pressure. Loosen 6 bolts, then remove ler (F), and release the internal cover (1). When doing this, the force of spring (2), so hold the he bolts. lve (3) and strainer (4), take out 3. cover may fly out under the cover down when removing t 4. After removing spring (2), va element (5). Inspect the bottom of the fi lter case for dirt, and remove it, if n not to let fall the dirt into the ushing oil. 5. Clean the removed parts in fl 6. Install the new element in the place where old element (5) was 7. installed.
Set valve (3), strainer (4) and spring (2) on top of the element. 8. Set cover (1) in position, pus h it down by hand, and install the cover with the mounting bolts . install the cover. ngine according to "STARTING 9. Screw in the oil filler cap and 10. To bleed the air, start the e ENGINE (PAGE 3-130)" and minutes. Stop the engine. run the engine at low idle for 10 11.