Maintenance section NOTICE Hold the drain port when the radiator drain valve is turned because the tank and the drain port are separated. 4. After draining the coolant completely, close the radiator drain valve and the block drain plug, fill the engine and the radiator full with a radiator cleaner, and clean the engine and the radiator. 5. Start and run the engine for 30 minutes. 6. Stop the engine and drain the cleaning solution into a suitable container. 7. Flush the system with clean water, until draining water is clear. 8. Close the drain valve and install the block drain plug. Fill coolant to top of the filler neck. 9. Start and run the engine to stabilize the coolant level.

See topic, “Coolant Level – Check” in “Every 10 Service hours or Daily”. 138