Engine Ch 1 page 144 Changing the pulley 501348 1. Remove the pulley using puller 501348 and drift 501349. 2. Press the pulley on until it is flush with the shaft end face. 501349 The pulley is removed Changing the sealing ring The pulley is pressed on If coolant has leaked out inside the housing behind the pulley, the sealing ring can be changed. 1. Place the pump with pulley on a flat and level surface. 501354 2. Fit puller 501354 using two M 8 x 65 mm bolts and drift 501349. Pull off the impeller. 501349 3. Split the carbon ring on the seal and remove the debris. The impeller is removed SHOP MANUAL MT41 - 12.2004