HOW-TO SECTION Cool dry chemical cooling system cleaner/conditioner (or equivalent sulfamic acid/sodium carbonate cleaner) and flushed. Coolant Inhibitor Test Intervals The coolant inhibitor level should be checked at the intervals listed in Table 28. Maintenance This section describes the procedures for maintaining the coolant inhibitor level and proper concentration. Table 28 Required Coolant Inhibitor Test Intervals If topping off is needed, add coolant which is identical to the initial fill coolant. To avoid injury from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Remove the cap slowly to relieve pressure.

Wear adequate protective clothing (face shield or safety goggles, rubber gloves, apron, and boots). Supplemental Coolant Additives for Fully Formulated Coolant The concentrations of some inhibitors will gradually deplete during normal engine operation. SCAs replenish the protection for cooling system components. The coolant must be maintained with the proper concentration of SCA. Detroit Diesel Power Cool maintenance SCAs are recommended. 96 All information subject to change without notice. (Rev.

May 2004) DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION Service Application Inhibitor Test Interval Motor Coaches 18,000 Miles (32,000 Kilometers) City Transit Coaches, Pick-Up and Delivery, Short Trip, and Emergency Vehicles 6,000 Miles (9,600 Kilometers) or 3 Months, whichever comes first Industrial, Continuous– Duty Generator Set and All Other Applications, except Standby Generator Set 500 Hours or 3 Months, whichever comes first Stand-By Generator Set 200 Hours or Yearly, whichever comes first