SERIES 40 ENGINE OPERATOR'S GUIDE Nitrite levels must be within the ranges listed in Table 25. over-concentration. This condition must be corrected by immediate draining and flushing of the cooling system. Refill the system with new fully formulated or pre-charged coolant. Check the nitrite concentration level at the next maintenance interval with a Power Trac 3–Way Test Strip. NOTICE: Failure to properly maintain coolant with SCA can result in damage to the cooling system and its related components. Conversely, over-concentration of SCA inhibitor can result in poor heat transfer, leading to engine damage. Always maintain concentrations at recommended levels.
Do not use traditional SCAs with OAT coolant. SCA Test Procedures Detroit Diesel Power Trac 3–Way Coolant Test Strips should be used to measure nitrite and glycol concentrations. Part numbers are listed in Table 55. Cavitation/corrosion is indicated on the strip by the level of nitrite concentration. Freeze/boil over protection is determined by glycol concentration. Additional SCA must be added to the coolant when it becomes depleted, as indicated by a nitrite concentration of 900 PPM or less. If the nitrite concentration is greater than 900 PPM, do not add additional SCA .
If the nitrite concentration is above 3200 PPM, the system is over-inhibited and should be partially drained and filled with a 50/50 mix of water and EG or PG. In this case the EG or PG should contain no inhibitors and should conform to ASTM D4985. This will dilute the over-concentrated inhibitors. NOTE: In non-OAT systems, nitrite concentration of 5000 PPM or higher on a Series 40 engine suggests problematic additive All information subject to change without notice. (Rev. May 2004) 99 DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION