SERIES 40 ENGINE OPERATOR'S GUIDE LUBRICATION AND PREVENTIVE MAINTENANCE INTERVALS The following is intended as a guide for establishing preventive maintenance intervals. The recommendations given should be followed as closely as possible to obtain long life and optimum performance from your engine. Maintenance intervals indicated are time (hours) of actual operation. just been stopped and is warm, wait approximately 20 minutes to allow the oil to drain back into the oil pan before checking. Add the proper grade of oil to maintain the correct level on the dipstick. See Figure 11 for the current oil level gage. When using this dipstick, keep the oil level within the cross-hatched area.
The intervals shown apply only to the maintenance functions described. These functions should be coordinated with other regularly scheduled maintenance. The “Daily” instructions apply to routine or daily starting of the engine. They do not apply to a new engine or one that has been operated for a considerable period of time. For new or stored engines, refer to Restoring an Engine to Service after Extended Storage in this guide. Figure 11 Current Oil Level Gage See Figure 12 for the former oil level gage. When using this dipstick, keep the oil level between the “Full” and “Add” lines.
Preventive maintenance other than the “Daily” checks should be performed by authorized Detroit Diesel service outlets. These outlets have the trained personnel and special tools to properly perform all services. Item 1 – Lubricating Oil Check the oil level daily with the engine stopped. If the engine has All information subject to change without notice. (Rev. May 2004) 53 DDC-SVC-MAN-0057 0305 Copyright © 2003 DETROIT DIESEL CORPORATION