. ATTACHMENTS, OPTIONS MACHINE MONITOR WITH LOAD METER ATTACHMENTS, OPTIONS MACHINE MONITOR WITH LOAD METER 3. This is the second load. tons. 4. This is the third load. This is 3.0 tons over the target amount, so -3.0 tons is displayed. REMARK 6 - 47 d load. ucket is 4.9 tons. ns, so the next target load i s displayed as 2.0 oad. asuring the load in the buc ket is 5.0 to 5. The target load i the display chan The target value the loading of th 6. Load the target bucket. When this is don 7. After loading, lo to weigh the am remaining in the s displayed as -3.0 tons, an d after 3 se conds, ges to the display shown o n the right. of 2.0 tons is the target loa d after com pleting e second bucket.

of 2.0 tons from the 5.0 tons loaded in the e, "2.0" flashes for the target load. wer the lift arm and then rai se it again i n order ount remaining in the buc ket. The amoun played. . amoun bucket is weighed and dis The amount remaini ng in the bucket is 3.5 tons The target load is 2. 0 - (5.0 - 3.5) = 0.5 tons of 0.5 tons is displayed. The next target load If 2.2 tons is loade d when the target load is 2.0 tons, and the amount remaining in the bucket is displayed as 2.8 tons (5. 0 - 2.2), the target load has b een exceeded, so the alar m buzzer s ounds. At the same time, "T ARGET OVER" is displaye d on the ch aracter display. cancel switch to stop the alarm buzzer.

Push the load meter cancel switch to stop the a larm buzze Note that the alarm b uzzer does not stop when the starting switch is turned to the OFF position. of 0.5 tons from the 3.5 ton s loaded in the bucket. er the lift arm and then rais e it again in order t o weigh the amount remain ing in the bucket. The g in the bucket is weighed and displa yed.